Quantification of myocardial fibrosis by digital image analysis and interactive stereology

Dainius Daunoravicius1*, Justinas Besusparis2, Edvardas Zurauskas12, Aida Laurinaviciene2, Daiva Bironaite3, Sabine Pankuweit4, Benoit Plancoulaine5, Paulette Herlin1, Julius Bogomolovas6, Virginija Grabauskiene1 and Arvydas Laurinavicius12

Author Affiliations

1 Vilnius University Medical faculty, Department of Pathology, Forensic Medicine and Pharmacology, M. K. Ciurlionio 21/27, Vilnius 03101, Lithuania

2 National Center of Pathology, Affiliate of Vilnius University Hospital Santariskiu Klinikos, Vilnius, Lithuania

3 Department of Stem Cell Biology, Center for Innovative Medicine, State Research Institute, Vilnius, Lithuania

4 Department of Cardiology, University Hospital Giessen & Marburg, Marburg, Germany

5 Path-Image/BioTiCla, University of Normandy, Unicaen, Caen, France

6 Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany

For all author emails, please log on.

Diagnostic Pathology 2014, 9:114  doi:10.1186/1746-1596-9-114

Published: 9 June 2014

Abstract

Background

Cardiac fibrosis disrupts the normal myocardial structure and has a direct impact on heart function and survival. Despite already available digital methods, the pathologist’s visual score is still widely considered as ground truth and used as a primary method in histomorphometric evaluations. The aim of this study was to compare the accuracy of digital image analysis tools and the pathologist’s visual scoring for evaluating fibrosis in human myocardial biopsies, based on reference data obtained by point counting performed on the same images.

Methods

Endomyocardial biopsy material from 38 patients diagnosed with inflammatory dilated cardiomyopathy was used. The extent of total cardiac fibrosis was assessed by image analysis on Masson’s trichrome-stained tissue specimens using automated Colocalization and Genie software, by Stereology grid count and manually by Pathologist’s visual score.

Results

A total of 116 slides were analyzed. The mean results obtained by the Colocalization software (13.72 ± 12.24%) were closest to the reference value of stereology (RVS), while the Genie software and Pathologist score gave a slight underestimation. RVS values correlated strongly with values obtained using the Colocalization and Genie (r > 0.9, p < 0.001) software as well as the pathologist visual score. Differences in fibrosis quantification by Colocalization and RVS were statistically insignificant. However, significant bias was found in the results obtained by using Genie versus RVS and pathologist score versus RVS with mean difference values of: -1.61% and 2.24%. Bland-Altman plots showed a bidirectional bias dependent on the magnitude of the measurement: Colocalization software overestimated the area fraction of fibrosis in the lower end, and underestimated in the higher end of the RVS values. Meanwhile, Genie software as well as the pathologist score showed more uniform results throughout the values, with a slight underestimation in the mid-range for both.

Conclusion

Both applied digital image analysis methods revealed almost perfect correlation with the criterion standard obtained by stereology grid count and, in terms of accuracy, outperformed the pathologist’s visual score. Genie algorithm proved to be the method of choice with the only drawback of a slight underestimation bias, which is considered acceptable for both clinical and research evaluations.

Virtual slides

The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/9857909611227193 webcite

Keywords:
Cardiac; Fibrosis; Quantification; Digital; Stereology