Email updates

Keep up to date with the latest news and content from Diagnostic Pathology and BioMed Central.

This article is part of the supplement: 22nd European Congress of Pathology European Society of Pathology (ESP) Working Group: Information Technology (IT) in Pathology Precongress Meeting

Open Access Oral presentation

Standards in virtual microscopy: from tissue processing to image acquisition and visualization

Gian Kayser1*, Jürgen Görtler2, Nicolas Kluge3, Thorsten Wiech1, Martin Werner1 and Klaus Kayser4

Author affiliations

1 Institute of Pathology, University of Freiburg, Freiburg, Germany

2 IBM, Deep Computing, Amsterdam, The Netherlands

3 Black Forrest Eye-Clinic, Schramberg, Germany

4 Institute of Pathology (UICC-TPCC), Charite, Berlin, Germany

For all author emails, please log on.

Citation and License

Diagnostic Pathology 2010, 5(Suppl 1):S10  doi:10.1186/1746-1596-5-S1-S10

The electronic version of this article is the complete one and can be found online at: http://www.diagnosticpathology.org/content/5/S1/S10


Published:9 April 2010

© 2010 Kayser et al; licensee BioMed Central Ltd.

Oral presentation

With the development of a new generation of slide scanner fort he generation of whole digital slides this technique is on its verge into routine histopathological diagnostics. Therefore the demand for standardized image acquisition and display needs to be fulfilled. Upon a physical and physiological basis the maximum performance are to be the cornerstones of this demand. Since with virtual slides huge data amounts have to be handled image compression is also an important issue. Therefore we analyzed the impact on jpeg image compression in 50 cases on 1) highest usable magnification, 2) security of diagnosis, 3) scan time and 4) data compression. The slides were digitized using a Zeiss MiraxScan in 11 different available qualitysteps (100%, 90%, 85%, 80%, 70%, 60%, 50%, 40%, 30%, 20%, 10%) and diagnosis was made for each case by three different pathologists. Throughout no misdiagnoses were made, but diagnostic security was rated as “good” only in qualitysteps of 40 % and higher in all cases. From this qualitystep upwards magnifications of 40x were also rated as “good”. Concerning scanning times a significant decrease in time was already observed by compression in qualitystep 90% and decreased further with decreased dataamount indicating a dependency on networkspeed. Furthermore, compressionrates of approximately 20% already in the 90 % qualitystep were obtained and decreased further to 8 % in the 10 % qualitystep. In conclusion the following standards for acquisition of virtual slides are required to 1) a pixel resolution of 0,2 x 0,2 µm2, 2) for the Mirax scan compression with qualitysteps of 40 to 80 % are acceptable for routine histologic diagnosis. For display of virtual slides we propose the successive technical requirements: 1) monitor resolution of > 4 megapixel, 2) contrast ratio of > 3000 : 1. As jpg-compression is a flexible compression standard, standardized compression modes for all slide scanners should be implemented.